AC INFINITY PRODUCTS RACK FANS The CLOUDPLATE series rack fan system is designed for quietly cooling a wide range of audio, video, home theater, network, and IT equipments racks. The model features a thermal controller with intelligent programming that will automatically adjust the fan speeds in response to changing temperatures. Sep 15, 2018 Buy AC Infinity CLOUDPLATE T2, Rack Mount Fan 1U, Top Exhaust Airflow, for cooling AV, Home Theater. This complete kit includes the 1U fan unit, corded 6-ft thermal probe, user’s manual, rack mount screws, cage nuts, and corded 6-ft power plug cord. Intelligent Cooling.
Advertising
6
Installer will be asked to select Accessories. Packaged Products will be automatically identified and the Installer will be asked to
select Accessories. Proceed to Selecting Accessories. NOTE: If the variable--speed indoor equipment (furnace or fan coil) cannot be found, the User Interface will display “CANNOT COMMUNICATE WITH INDOOR UNIT”. This MUST be corrected before the initial power up sequence can continue. If indoor unit is found, but outdoor unit is not found, “OUTDOOR UNIT NOT IDENTIFIED” will appear. Proceed to the next section for Outdoor Unit Identification.
Selecting Outdoor Unit
OUTDOOR UNIT
NOT IDENTIFIED
SELECT TYPE:
NONE
NONE, AC, HP
PRESS +/- TO MAKE
SELECTION
CONTINUE
OUTDOOR UNIT
ENTER HEAT PUMP
SIZE
36000 BTU
18000 TO 60000 BTU
PRESS +/- TO MAKE
SELECTION
BACK CONTINUE
OUTDOOR UNIT
HEAT PUMP
Ac Infinity Fan Amazon
ENTER NUMBER OF
SPEEDS, 1 or 2:
1
PRESS +/- TO MAKE
SELECTION
BACK CONTINUE
A03196
Fig. 17 -- Selecting Outdoor Unit
If there is no communicating outdoor unit, the screen, shown in
Fig. 17, will appear. Press either Time or Temp +/-- buttons to select AC (air conditioner), HP (heat pump), or None (no unit
installed). Press right--side button to continue to next screen. If either AC or HP has been selected as the outdoor unit type, the
middle screen will appear (see Fig. 17). Press either Time or Temp
+/-- buttons to select appropriate BTU size of outdoor unit, then press right side button to continue. If a NIM (Network Interface
Module) is applied for non--communicating two--stage outdoor equipment, select 1 or 2--stage compressor operation, and press
right--side button to continue. NOTE: Range of outdoor unit BTU selection is limited by model number of indoor unit installed. The Infinity Control will not allow an outdoor unit size that is not supported by the installed indoor unit. NOTE: On new system installations, the model and serial number will be recognized and displayed. On any indoor/outdoor board replacements, the equipment will be recognized but the exact model/serial number will not be displayed.
Selecting Electric Heater
ELECTRIC HEATER
NOT IDENTIFIED
ENTER SIZE:
5 KW
NONE, 5,10,15 KW
PRESS +/- TO MAKE
SELECTION
BACK CONTINUE
A03197
Fig. 18 -- Selecting Electric Heater
If the equipment is a fan coil, packaged heat pump, or packaged
AC and the electric heater is not self--identifying, “ELECTRIC HEATER NOT IDENTIFIED” will appear (see Fig. 18). Press
either Time or Temp +/-- buttons to select appropriate size of electric heater installed, then press right--side button to continue.
An asterisks (*) will appear next to electric heater sizes that may cause excessive airflow. NOTE: Range of electric heaters available is limited by model number of the equipment installed. The Infinity Control will not allow an electric heater size that is not supported by the installed equipment.
Hydronic Heat Applications
The --B non--zoned model of the Infinity Control supports 2 types
of Hydronic Heat applications:
1. Hot water coil in combination with an FE fan coil and heat
pump, or hot water coil as sole heat source with an FE fan coil.
2. Non--zoned FE fan coil combined with radiant hot water
heat.
In either application, a Hydronic Heat kit should be installed in place of an electric heater. See FE fan coil Product Data for
accessory part number. The system will identify that Hydonic Heat has been installed during the initial commissioning process. The
system will treat the hot water coil as either auxiliary heat in a heat pump application, or the sole heat source. Setup options for
Hydronic Heat applications are described in the Setup section of
this instruction.
Selecting Accessories
ACCESSORIES
HUMIDIFIER
INSTALLED?
YES
PRESS +/- TO MAKE
SELECTION
BACK CONTINUE
ACCESSORIES
U.V. LIGHTS
INSTALLED?
YES
PRESS +/- TO MAKE
SELECTION
BACK CONTINUE
ACCESSORIES
AIR FILTER TYPE:
EAC
EAC
MEDIA
MEDIA + EAC
PRESS +/- TO MAKE
SELECTION
CONTINUE
AIR FILTER MEDIA TYPE
HUMIDIFIER INSTALLED?
U.V. LIGHTS INSTALLED?
A03198
Fig. 19 -- Accessories —UV Lights
Once the indoor and outdoor equipment have been found or entered, the following screens will appear allowing the Installer to
select the “AIR FILTER TYPE; HUMIDIFIER INSTALLED”; and “UV LIGHTS INSTALLED” (See Fig. 19). Use either Time or
Temp +/-- buttons to make appropriate selections in the highlighted area on the display screen. Press right--side button to continue (or
advance) to the next screen. Air Filter Type This accessory screen will appear first. The installer will need to
enter the type of filter (MEDIA, EAC, or both). See Table 1 and make a selection using Time or Temp +/-- button, then press
right--side button to continue.
Table 1 – Filter Selection
INSTALLED FILTER
MENU
SELECTION
1 inch to 4 inch media
MEDIA
High voltage EAC
EAC
High voltage EAC + 1 to 4 inch media
MEDIA + EAC
Infinity Air Purifier
MEDIA
Humidifier Installed This will appear after the Air Filter Type screen. Select whether a
humidifier is installed on the system, YES or NO, then press right--side button to continue.
CCUI
D
01
--
B
Advertising
Popular Brands
Popular manuals
Advertising
10
Setup -- Fan Coil
HP/AC Airflow:
S
COMFORT (default) Cooling airflow is varied depending on humidity and temperature demand settings. This selection enables the full dehumidify and comfort capabilities of the system. When COMFORT is not selected, the unit will not run reduced airflows for dehumidification. Heat Pump airflow is varied depending on outdoor temperature to maximize comfort.
S
EFFICIENCY -- fixed airflow used to achieve specified ratings -- no dehumidification airflow reduction. This is nominally 350 CFM/ton, but will vary if a 2--stage outdoor unit is used.
S
MAXIMUM -- 400 CFM/ton. No dehumidification airflow reduction.
Dehum Airflow:
S
NORMAL (factory default) -- When equipment is running to dehumidify, the airflow is allowed to adjust to a minimum to satisfy the dehumidification call.
S
HIGH -- Minimum airflow during the dehumidify mode is increased to reduce duct and register sweating. Also increases minimum airflow during normal cooling operation to reduce duct sweating.
Heater Size:
S
(choices dependent upon fan coil model)
This will show the heater size entered during the start--up process.
This value can be changed to another value (limited by the model
number of the fan coil). If the electric heater is self--identifying, this value is not shown. Elect Heat Lockout
S
NONE (default)
S
+5 to 55_F / --15 to 13_C
Outside temperature above which the electric heat will not operate
except for defrost. G Terminal This setup option selects desired operation when the R--G circuit changes state on the fan coil control board depending on setup.
S
DISABLED (Default)
S
FAN -- turns on fan to selected fan speed when G terminal is energized. See Fig. 26.
S
FAN SPEED -- select Low, Med, High for all zones when G terminal is energized
S
SHUTDOWN -- shuts off fan and equipment when initiated. This function is not intended for emergency fire shutdown. It may be activated by a dry contact from an external device such as a float switch or a relay. User selects whether the contact is NC -- normally closed (default) or NO -- normally open. User Interface displays SYSTEM MALFUNCTION on screen and registers G terminal shutdown event in Last 10 System Events. See Fig. 27.
Setup -- Heat Pump / AC
Cooling Lockout:
S
NONE (default)
S
45_F / 7_C
S
Ac Infinity Cooling Fan
50_F / 10_C
S
55_F / 13_C
Outside temperature below which cooling will not be provided. Low Ambient Cooling:
S
NO (default)
S
YES
Selecting YES will enable the low ambient cooling operation in
the outdoor unit. This setting is only available with communicating outdoor units and with Cooling Lockout set to NONE. For detailed sequence of operation, see outdoor unit installation
instructions. Entered Size:
S
(dependent on indoor unit model)
Size of the outdoor unit entered during the start--up process. If the outdoor unit is a communicating model, this value will not be
shown. This size can be changed here but is limited to sizes that the indoor unit can handle. Defrost Interval:
S
30 minutes
S
60 minutes
S
90 minutes
S
120 minutes (default)
S
Auto--Defrost interval optimized by outdoor control (default for communicating HP)
Time interval at which defrost cycles can occur on a heat pump. High Cool Latch:
S
NONE (default)
S
On
S
80 to 110_F / 27 to 43_C
Outside temperature above which only the high stage (of a 2--stage
outdoor unit) will run when cooling. High Heat Latch
S
OFF (default)
S
On
S
20 to 50_F / --7 to 10_C 2 --stage heat pump runs only high stage heating below a selectable outdoor temperature. Selections from 20 to 50_F / --7 to 10_C are available in 5_F / 3_C increments.